Device support
Programmers, coding boards, switches, NICs and other hardware
The poster runs temporary event networks and has twice hit heavy frame errors on 10G links between MikroTik and Cisco switches. About a year earlier a Cisco Catalyst 2960-S with 10G uplinks connected to a MikroTik CRS317-1G-16S+ showed CRC errors on the Cisco side and swapping cables did not help…
On a Cisco Nexus N9K-C93180YC-FX, QSFP-40G-SR-BD BiDi modules are not detected at all: nothing appears in the logs when they are inserted and they are absent from 'show interface transceiver', whereas QSFP-40GE-LR4 modules in the same ports are logged and listed normally. Several QSFP-40G-SR-BD…
The poster asked whether a 10G SFP+ SR or LR optic in one switch can auto-negotiate down to 1G to link over fiber with a 1G SFP in another switch, and if not, how to attach a handful of 1G optical connections from a 1G switch to a 10G switch. They understood that Cisco SFP+ optics run only at 10G…
In the poster's data center several Cisco CWDM SFP/GBIC links stopped working: some ports went err-disabled (one with link-flap as the cause) and others simply showed notconnect. Troubleshooting included shut/no shut, reseating the modules, moving the CWDM SFPs to other ports, replacing the patch…
The poster wanted to use a 40G QSFP+ to 4x10G SFP+ DAC breakout cable on a Cisco Catalyst 9500-32QC-E running IOS XE 17.6.4 (Bengaluru). The 'hw-module breakout' command is rejected; in global configuration only 'hw-module slot' and 'hw-module subslot' are offered. The switch is not running…
The poster could not find Cisco documentation describing how to set the frequency or ITU channel of a DWDM-SFP10G-C tunable 10G SFP+. A follow-up question asked whether a CPAK-100G-LR4 in a CRS-X 4-port 100GE LAN/OTN card could be tuned to a wavelength and connected directly to a ROADM of an…
A Cisco Catalyst 3850-24XS with an SFP-10G-LR (1310 nm) connects over a single-mode cross-connect to a Tier-1 carrier's layer-2 DWDM equipment in the same data center. When the carrier shuts the circuit down, TenGigabitEthernet2/0/23 goes 'down, line protocol is down (notconnect)' yet 'show…
2votes
2comments
182views
The poster (in a machine-translated post from the Spanish-language community) tried to connect two Cisco Business CBS350-24T-4X switches through their SFP+ ports using MikroTik XS+2733LC15D modules. No connectivity is established and the ports end up blocked by the switch's Link Flap Prevention…
The poster connected a Dell server to a Cisco Catalyst C9500-48Y4C (IOS XE 17.9.3) using a Dell L56SF018-SD-R 3 m DAC (DAC-SFP-3M). The cable is not in Cisco's optics compatibility matrix, and 'show interface status' shows port TwentyFiveGigE1/0/35 as err-disabled. Logging shows…
4votes
4comments
165views
Two Cisco Catalyst C1200-48T-4X switches were connected back-to-baack with Cisco SFP-10G-LR modules in the ge49/te1 SFP+ slots. Both switches recognize the transceivers, the interfaces are administratively up, both ends transmit light and the DOM optical values are good, yet no link is established…