Top questions
Popular discussions about programming, compatibility and testing of optical transceivers.
3votes
4comments
163views
We are building out two racks and the switching is settled: a pair of M4500-48XF8C as the leaves with M4350 underneath. What is not settled is the optics BOM. NETGEAR does not put its own label on 25G or 100G modules, and I would rather not discover after delivery that the SFP28 ports dislike what…
3votes
7comments
134views
We are reusing a pile of 10G optics on a whitebox switch running SONiC, so a few QSFP28 cages are fitted with QSA-style adapters (10GTek QSA-100A) carrying plain 10G SFP+ modules. Mechanically and electrically this is fine. The management side is where it falls apart. switch: 1U whitebox, SONiC…
Some Cotsworks SFF fibre modules ship with invalid data in the first EEPROM bytes (physical ID, extended physical ID, connector type) and with checksums programmed before the fields were finalised, so the Linux phy/sfp driveer does not detect them as valid modules. A kernel fixup rewrites the three…
The poster's newly acquired Cisco Catalyst 9300 (with an 8-port 10G SFP+ network module) would not link to a Cisco Catalyst 4503-E tat only has 1G SFP ports. Suspecting a 10G-versus-1G speed mismatch, the poster tried to force the 9300's 10G SFP to operate at 1G with the 'speed' command, but the…
For a deployment on Dell PowerEdge R630 and C4140 servers the poster had Intel X520-SR2 adapters (E10G42BFSR) fitted with the bundled Intel FTLX8571D3BCV-I3 10GBASE-SR SFP+ modules (850 nm, 300 m multimode). The uplink switch is a Huawei Quidway 9300 whose SFP+ ports carry 10GBASE-LR (1310 nm)…
We are refreshing the core of a small office and put in a pair of Aruba CX 6200F. The link between the two switches is meant to be a 10G trunk on the SFP+ uplinks, and I cannot get either box to admit that 10G exists on that port. 2x Aruba CX 6200F Switch Series, trunk on port 1/1/25 Cisco…
3votes
5comments
143views
We recode a small batch of modules for customer hosts most months, nothing exotic: read the original page, write the vendor string the host wants, put the module in the switch and move on. One module out of the current batch refuses every write while reading back perfectly, and before I bin it I…
4votes
4comments
150views
I keep a shelf of pulled SFPs at home and I would like to be able to read their EEPROM, repair a module whose checksum got mangled, and occasionally recode one for a switch that is picky about vendor strings. Buying a commercial programmer for a handful of modules a year makes no sense here, so I…
An Aruba/HPE 2530-48G-2SFP+ on firmware 16.01.0012 logged Port contains a transceiver not made by Hewlett Packard Enterprise with the advice to use onlly genuine transceivers, and refused the modules; ironically one of the rejected transceivers was HP-branded. The poster asked whether a command…
A MikroTik CSS610-8P-2S+ (SwOS Lite) needed to connect its SFP+ ports to a Cisco Nexus 5596UP. The ports showed the transceivers in the web UI but no link, after trying several fibre cables and transceivers. The switch web UI listed vendor and type for each module, yet the port stayed at no-link…
On an Intel S2600WFT board the X722 10GbE SFP+ controller (rev 09, NVM 3.31 0x80000d31 1.1767.0) refused ethtool -m with Cannot get module EEPROM information: Invalid argument, and the kernel logged Module EEPROM memory read not supported. Please update the NVM image. The behaviour was identical…
Four HP ProCurve 6120XG blade switches (516733-B21) refused J9150A 10G SR SFP+ transceivers that the datasheet lists as supported; show tech transceivers reported them as unsupported. The switches ran Z.14.56. The poster asked whether a firmware upgrade or a configuration setting was needed…
An ODI DFP-34X-2C2 GPON ONU SFP failed to advertise its 2500BASE-X capability because its EEPROM (or virtual EEPROM) did not provide correct speed information to the Linux sfp driver, so the interface did not run at the expected rate. A kernel patch adds a quirk to force the right speed. Hardware…
3votes
4comments
109views
We took over a pair of ZS3-2 controllers together with the shelves behind them, and I am the one who has to order optics before they go back into service. The controller service manual is very short on this point: it lists the NIC and HBA options, and for the 10GbE SFP+ card it names exactly two…
SFP+ DACs linked MikroTik-to-MikroTik and OLT-to-OLT, but between a V-SOL EPON OLT 16008D and a CCR2004-1G-12S+2XS or CRS326-24G-2S+RM the OLT reported the interface as disconnected. The same DACs were recognised on both platforms, so the poster suspected a cross-vendor auto-negotiation or…