2votes
2comments
85views

MDS 9148S/9148T on NX-OS 8.4(2a)/8.4(2f): GBIC/SFP checksum error and IF_UNSUPPORTED_TRANSCEIVER with third-party FC SFPs

A Dell Connectrix (rebadged Cisco) MDS 9148S or 9148T running NX-OS 8.4(2a) or 8.4(2f) keeps some FC ports dowwn and logs %PORT-3-IFUNSUPPORTEDTRANSCEIVER: Transceiver for interface fcx/y is not supported, %KERN-3-SYSTEMMSG: GBIC/SFP checksum error ref port:30 - kernel and %PORT-5-IFDOWN…

4votes
2comments
48views

Nexus 7700 to Catalyst 9500 with third-party 100G QSFP28: MD5 warnings are cosmetic, the real blocker is FEC cl91

A 100G link between a Nexus 7700 (Ethernet3/2) and a Catalyst 9500 (HundredGigE1/0/49) used third-party LR4 modules. With service unsupported-transceiver on both boxes the Nexus still logged %ETHPORT-3-IFUNSUPPORTEDTRANSCEIVER and an 'SFP security check: MD5 failed' line, and the interface stayed…

3votes
2comments
75views

Nexus 3064 (N3K-C3064PQ-10GX): third-party SFP+ and DACs need no negotiate auto and duplex full, or the link never appears or flaps

Setting up an N3K-C3064PQ-10GX on NX-OS 7.0.3.I4.6 with non-Cisco SFP+ modules and DAC cables up to 5 m to servers: after service unsupported-transceiver some ports still show no link, or the link disappears after a while, and one port endd in 'Error disabled. Reason: Too many link flaps'. Which…

2votes
2comments
121views

Do DrayTek Vigor2962 and VigorSwitch G2540x take third-party SFP+ optics, or only DrayTek modules?

We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…

3votes
4comments
110views

Oracle ZFS Storage ZS3-2: only X2129A and X5562A-Z are listed for the X1109A-Z 10GbE NIC

We took over a pair of ZS3-2 controllers together with the shelves behind them, and I am the one who has to order optics before they go back into service. The controller service manual is very short on this point: it lists the NIC and HBA options, and for the 10GbE SFP+ card it names exactly two…

6votes
6comments
210views

Third-party DWDM SFP+ stays down on an Arista 7050T with EOS 4.10.6 - anything short of patching the image?

We run a small regional network and pulled a spare 7050T out of stock to use as a DWDM aggregation box. Arista-coded DWDM optics for it quote close to the price of the switch, so we bought third-party DWDM SFP+ instead, and now the switch will not talk to them. Arista 7050T, EOS 4.10.6 generic…