3votes
1 answer
95views

Receiver-overload warnings on a 10G SFP link: optical power is not negotiated; newer MMA2P00-AS revisions run hotter

An embedded device with a 10GbE SFP transceiver kept logging power warnings above 800 mW and occasional errors when fed by an NVIDIA/Mellanox MMA2P00-AS 10/25G transceiver over a 2 m OM3 LC patch. The poster assumed transmit power is negotiated between the two ends and asked whether a failed…

3votes
1 answer
72views

Aruba 2540 uplink ports 51-52 stay Down on an inter-building run while a 2530 links the same modules

I look after a two-building site and the access switches were replaced with Aruba 2540s a while back. The fibre between the buildings has not been touched, but since the swap the uplink refuses to come up. Aruba 2540 on our side, ports 51 and 52 used for the uplinks Aruba J4858D 1000SX in the 2540…

5votes
4comments
202views

27 km span on an MES3324F: the same modules link up in an MXA-64 but Eltex takes the port to PORT_SUSPENDED

A link between two of our sites: about 27 km of single-mode fiber, MES3324F on both ends. Installed a pair of 1550 nm FANG HANG SFPs sold as 40-km modules. The link comes up, lives for a few dozen seconds, and drops, over and over, until the port gets blocked. 2 x Eltex MES3324F, firmware 4.0.7 SFP…