Cannot link a Catalyst 9300 10G SFP+ port to a Catalyst 4503-E 1G SFP port

Asked Active Viewed 84 Original language: English
4

The poster's newly acquired Cisco Catalyst 9300 (with an 8-port 10G SFP+ network module) would not link to a Cisco Catalyst 4503-E tat only has 1G SFP ports. Suspecting a 10G-versus-1G speed mismatch, the poster tried to force the 9300's 10G SFP to operate at 1G with the 'speed' command, but the command is not accepted on SFP interfaces. The question was whether a 10G optic can be made to run at 1G so that it can talk to the 1G SFP on the 4503-E.

  • Hardware: Cisco Catalyst 9300 with 8-port 10G SFP+ network module, Cisco Catalyst 4503-E
  • Transceivers: unspecified 10G SFP+, unspecified 1G SFP
  • Form factor: SFP+, SFP

Symptoms / messages:

no link between 10G SFP+ port and 1G SFP port
speed command rejected on SFP interface
10G vs 1G speed mismatch

Comments 3

Accepted answer

Accepted: no, an SFP's speed is fixed by the module type; a 10G optic cannot be forced to 1G.

1 United Statestxnode67US Original (English)

Accepted: there is no auto-negotiation on fiber, so both ends must use the same kind of SFP at the same speed, and the modules must be supported by each device.

3 United StatesedgewolfUS Original (English)

Many 10G ports are actually SFP+ ports that accept either a 1G or a 10G SFP, so if your 9300 module supports it, a 1G SFP in there can match the 4503-E - just make sure the optics are matched for media too (SX to SX, LX to LX).

0 IndiagigengIN Original (English)