CodingBox Q&A Ask question

SONiC on Nokia chassis line cards: non-CMIS 40G/100G optics need the SFF manager enabled

Asked Active Viewed 80 Original language: English
0

On Nokia chassis line cards running SONiC, 40G and 100G transceivers that use the older SFF management moodel (not CMIS) were not being provisioned by the platform monitor, so those modules were not driven properly. How was this addressed?

Comments 2

Check whether the platform enables the SFF manager alongside the CMIS manager. Nokia's platform change sets enable_xcvrd_sff_mgr to true in pmon_daemon_control.json for the relevant chassis.

2 Russiasfpsmith28RU Original (English)

A non-CMIS 40G/100G optic needs the SFF state-machine path. Verify that the installed SONiC platform package includes that change before diagnosing every uninitialised older-format module as defective.

3 KazakhstancoaxnerdKZ Original (English)
Log in to comment. Log in