CodingBox Q&A Ask question

Questions tagged “sonic”

10 questions
15 30 50 per page
1vote
2comments
69views

Z9332F SONiC 4x100G breakout: Intel DR4 QSFP-DD fails CMIS datapath with ConfigRejectedPartialDataPath, fixed by newer module revision

On a DellEMC Z9332F-O32 running SONiC master build using the CMIS manager a 400G Intel DR4 QSFP-DD module (SPTSHP2PMCDF) is broken out into 4x100G. All resulting 100G interfaces stay down although the module advertises both 400GAUI-8 and 100GAUI-2 applications. show interfaces transceiver status…

South Korea netrunner KR asked
3votes
2comments
45views

Z9332F SONiC: after dynamic port breakout, show interfaces status shows media type N/A and TRANSCEIVER_INFO is empty

On a DellEMC Z9332f-O32 running SONiC master with the affected dynamic-breakout implementation a 400G port is broken out with config interface breakout Ethernet0 4x100G. Afterwards shhow interfaces status prints N/A in the Type column for the new sub-ports (Ethernet2, Ethernet4 ...) insteda of the…

Netherlands opticguru22 NL asked
1vote
1comment
31views

SONiC test_check_sfp_using_ethtool fails on a Mellanox MSN4600C: Cannot get module EEPROM information: No such device

On a Mellanox MSN4600C (ACS-MSN4600C) running SONiC in a T1 topology, the test testchcksfpusingethtool failed because ethtool -m sfp[ID] returned rc=1 with Cannot get module EEPROM information: No such device, i.e. the module EEPROM was not accessible on that platform during the test. Hardware…

0votes
0comments
83views

Wedge100BF-32X on SONiC: 100G LR4 links back to back but not through the transport unless TX is patched first

We are handing a 100G circuit off to a core router through a leased optical transport system, and the port on our side refuses to come up. The same pair of modules links instantly on the bench, which is what makes this so irritating. Wedge100BF-32X (wedge100bf32x) running SONiC InnoLight…