2votes
1 answer
95views

10Gtek ASF-10G-T copper module: ethtool -m returns Operation not supported until the NIC firmware is updated

A customer with a 10Gtek ASF-10G-T 10GBASE-T transceiver could not read its EEPROM: ethtool -m ens802f0 returned Cannot get module EEPROM information: Operation not supported. The vendor attributed it to a firmware version mismatch between the NIC and the transceiver. Hardware involved: 10G NIC…

1vote
1comment
31views

SONiC test_check_sfp_using_ethtool fails on a Mellanox MSN4600C: Cannot get module EEPROM information: No such device

On a Mellanox MSN4600C (ACS-MSN4600C) running SONiC in a T1 topology, the test testchcksfpusingethtool failed because ethtool -m sfp[ID] returned rc=1 with Cannot get module EEPROM information: No such device, i.e. the module EEPROM was not accessible on that platform during the test. Hardware…

1vote
1comment
128views

ethtool -m on a Mellanox MT26448 (ConnectX-2) returns Input/output error: DOM readout not supported on EOL adapters

On Debian 8.11 (kernel 3.16) the poster ran ethtool -m on a Mellanox MT26448 adapter to read optical diagnostics (TX/RX power, temperature, voltage, thresholds) and got Cannot get module EEPROM information: Input/output error. Hardware involved: Mellanox MT26448 ConnectX-2, SFP+ optic with DDM…

2votes
1 answer
284views

ethtool -m on Intel X722 fails: Module EEPROM memory read not supported, please update the NVM image

On an Intel S2600WFT board the X722 10GbE SFP+ controller (rev 09, NVM 3.31 0x80000d31 1.1767.0) refused ethtool -m with Cannot get module EEPROM information: Invalid argument, and the kernel logged Module EEPROM memory read not supported. Please update the NVM image. The behaviour was identical…

5votes
1 answer
165views

Dell DD9900 in an HA pair doesn't see the SFP on ethMa: State UP, link status NO, Cannot get module EEPROM information

I run a backup storage system in a data center. A pair of DD9900 in HA, network ports on the NDC QLogic. After a reboot or reseating the module, port ethMa stops seeing the transceiver, and it's not a one-off - it's a stable, repeating pattern. Dell DD9900, DD OS 7.2.0.95, HA configuration NDC…

Russia portrunner91 RU asked
3votes
3comments
109views

ethtool -m fails on FS.com XXV710 NIC: "Module EEPROM memory read not supported" and NVM not updatable

On Ubuntu 18.04 (kernel 5.4.0, ethtool 5.3, i40e 2.8.20-k) the poster used 25G XXV710-based NICs bought from FS.com (FS part XXV710AM2-F2, Intel XXV710 chipset). Link and error-free wire-speed traffic worked, but reading a transceiver's DMI data with sudo ethtool -m enp4s0f0 failed with "Cannot get…