CodingBox Q&A Ask question

Questions tagged “pfsense”

8 questions
15 30 50 per page
2votes
1 answer
54views

pfSense on an 82599 (X520 clone) cannot negotiate 2.5G with an SFP+ RJ45 module to a cable modem

A pfSense router on a Supermicro R210 II with an AOC-STGN-i2S (82599-based X520 clone) was connected throguh an FS.com SFP+-to-RJ45 module to a cable modem with a 2.5 Gbps port. No link negotiation happened; pfSense offered only auto and 10G speeds and never 2.5G. Hardware involved: Supermicro…

3votes
1 answer
155views

Where to set hw.ix.unsupported_sfp=1 on a Netgate XG-7100 with third-party optics (loader.conf.local vs GUI tunables)

The poster had third-party SFP+ optics for both the on-board Intel X553 ports of a Netgate XG-7100 and an add-in X520-DA2 and had found that hw.ixgbe.unsupportedsfp=1 in /boot/loader.conf enables them. Questions: does it apply to both on-board and PCIe Intel ports, what is the difference between…

2votes
1 answer
106views

1G SFP on Intel X710 (pfSense, ixl) fails with unqualified module until the optic is recoded as Intel

On a Protectli Vault 6 with Intel X710 SFP+ ports (ixl0/ixl1) a 1G EZConn ETB43315-7S34-FR SFP showed no carrier. Logs contained Invalid advertised speed; valid flags are: 0x06, ixl1setlink: Error getting phy capabilities -37, aq error: 8 and Link failed because an unqualified module was detected!…

5votes
1 answer
134views

Supermicro E300-9A on pfSense Plus 22.05: ix2 and ix3 stay at no carrier with a DAC that links fine on a USW-Aggregation

My firewall is a Supermicro E300-9A running pfSense Plus 22.05, and both 10G SFP+ ports refuse to come up. Neither ix2 nor ix3 ever shows carrier, whatever I put in the cage. Hardware: Supermicro E300-9A, pfSense Plus 22.05 Ubiquiti DAC-SFP10-0.5M and a 10Gtek passive twinax cable Supermicro…

Indonesia sfpeng49 ID asked