25G SFP28 links only on the stack master until FEC is matched (5420 stack to VSP 7432)
In a Universal 5420 EXOS stack ulinked to VSP 7432 switches over a 100G-to-4x25G breakout, port 1:52 on the master comes up but the matching port 2:52 on the backup unit stays down in the same LAG. 1G, 10G and 25G DAC links are fine. What is different about the 25G fibre link on the standby slot?