插入 SFP-H25G-CU2M DAC 后 Catalyst C9300X-24Y 把 FEC 重置为 auto,导致到 FortiGate 的链路断开

Asked Active Viewed 314 AI translation from English
4

发帖人用一根 25G 的 SFP-H25G-CU2M DAC 把 Cisco Catalyst C9300X-24Y 连到一台 FortiGate 防火墙。每次插入这根 DAC,交换机都会记录 '%PLATFORM_PM-6-MODULE_INSERTED: SFP module inserted with interface name Twe1/0/23',紧接着是 '%PLATFORM_PM-6-DIFFERENT_MODULE_INSERTED: Warning: SFP module inserted in to the interface Twe1/0/23 differs from the previously inserted one. The port's fec configuration will be set to the default.'。FEC 设置随即被重置为 auto,而 FortiGate 不支持这个模式,链路始终起不来。用同一种线缆把两台设备各自的端口自环连起来,证实两端都具备 25G 能力;只有跨厂商搭配才会失败。

  • 硬件: Cisco Catalyst C9300X-24Y、Fortinet FortiGate 防火墙
  • 收发器: SFP-H25G-CU2M
  • 封装形式: SFP28、DAC

症状/报错信息:

%PLATFORM_PM-6-MODULE_INSERTED: SFP module inserted with interface name Twe1/0/23
%PLATFORM_PM-6-DIFFERENT_MODULE_INSERTED: Warning: SFP module inserted in to the interface Twe1/0/23 differs from the previously inserted one. The port's fec configuration will be set to the default.
FEC reverts to auto on module insertion
no 25G link to FortiGate

Comments 2

交换机的具体型号和软件版本是什么?在支持多种模块类型的多千兆端口上,这个警告其实是正常现象。FortiGate本身支不支持25G?另外可以试试用10G SFP模块——这样能证明问题不是Fortinet那边DAC兼容性的问题。

2 Brazilopticnerd31BR Show original (English) AI translation

这根SFP-H25G-CU2M真的是Cisco原厂的吗?非Cisco线缆有可能就是原因。FEC协商是端口自动协商交互的一部分,所以可以在Twe1/0/23上试试'no negotiation auto',然后手动固定端口参数。

4 Chinacorebyte73CN Show original (English) AI translation