CodingBox Q&A Ask question

Questions tagged “intel-x520”

8 questions
15 30 50 per page
1vote
1 answer
128views

CSS610-8G-2S+IN shows link on SFP+ ports but Intel X520 NICs never see it; SwOS 2.13rc12 works, later builds do not

A MikroTik CSS610-8G-2S+IN showed an active SFP+ link, but Intel X520-DA1/DA2 NICs (Windows, Linux, ESXi) reported no link, reproducibly across multiple transceiver pairs, DACs and two cards. Firmware 2.12, 2.13rc6, 2.13rc12, 2.13rc25 and the final 2.13 were tested. Hardware involved: MikroTik…

3votes
1 answer
155views

Where to set hw.ix.unsupported_sfp=1 on a Netgate XG-7100 with third-party optics (loader.conf.local vs GUI tunables)

The poster had third-party SFP+ optics for both the on-board Intel X553 ports of a Netgate XG-7100 and an add-in X520-DA2 and had found that hw.ixgbe.unsupportedsfp=1 in /boot/loader.conf enables them. Questions: does it apply to both on-board and PCIe Intel ports, what is the difference between…

2votes
1 answer
319views

Proxmox on a Dell R720 with X520 rNDC: ixgbe allow_unsupported_sfp=1 does not take effect for Cisco SR modules

A Dell R720 with the integrated i350/X520 daughter card ran Proxmox VE; Cisco-branded 10G multimode LC SFP+ modules that worked elsewhere were rejected as unsupported. Adding options ixgbe allowunsupportedsfp=1 to the module options had no visible effect. Respondents walked through GRUB kernel…