CodingBox Q&A Ask question

Questions tagged “Huawei”

7 questions
15 30 50 per page
0votes
1 answer
18views

Huawei S6700 iStack fails because different transceiver types are mixed on the stacking ports 45-48

A Huawei S6700 iStack did not form because the optical modules on the dedicated stacking ports 45-48 were of different types; the platform requires identical transceivers on those ports. The four ports 45-48 are the fixed stacking ports, and mixing, for example, an SR module on one and an LR module…

0votes
1 answer
21views

Huawei 25GE ports: 10G SFP+ and short copper cables need RS-FEC enabled or the interface stays down

On Huawei switches with 25GE ports the poster asked about using SFP+ transceivers and copper cables; per the troubleshooting docs, when a non-1 m copper cable is connected to a 25GE interface the RS-FEC function must be enabled or the interface goes Down, and mixing different optical modulles at…