CodingBox Q&A Ask question

ConnectX-7 menahan modul QSFP112 400G SR4 pihak ketiga di low-power state: validasi CMIS/EEPROM gagal

Asked Active Viewed 217 AI translation from English
2

Modul QSFP112 400G SR4 di ConnectX-7 (MCX755106AC-HEAT) dengan kabel MPO-12 Type-B menunjukkan module state Ready dan data path DPActivated, tapi mlxlink --show_module melaporkan State = Disable, Supported Cable Speed = 0x00000000, Compliance = Unspecified/Undefined, Power Class 1.5 W (terlalu rendah untuk 400G), Vcc sekitar 120 mV alih-alih 3.3 V dan RX power -40 dBm di semua lane dengan rekomendasi Cable speed not enabled, sementara ujung satunya mengirim sekitar +3 dBm.

  • Hardware: NVIDIA ConnectX-7 MCX755106AC-HEAT
  • Transceiver: QSFP112 400G SR4 pihak ketiga
  • Form factor: QSFP112

Gejala / pesan:

Cable speed not enabled
Supported Cable Speed = 0x00000000
Power Class 1.5W
RX power -40 dBm
module held in low-power mode

Comments 2

Accepted answer

Firmware NIC-nya mendeteksi modulnya tapi memperlakukannya sebagai non-compliant (media compliance code tidak valid, speed bitmap nol, power class dan host electrical interface yang salah di halaman CMIS) dan sengaja menahannya di low-power mode tanpa mengaktifkan RX. Cek dukungan firmware untuk QSFP112 SR4, set ALLOW_UNSUPPORTED_CABLES, perhatikan apakah Vcc mencapai 3.3 V, dan bandingkan dengan modul yang qualified dari NVIDIA.

8 Spainrxadmin25ES Show original (English) AI translation
Log in to comment. Log in