Catalyst 3850-24XS的10G端口显示down,但DOM显示来自运营商DWDM的RX功率正常

Asked Active Viewed 174 AI translation from English
5

一台Cisco Catalyst 3850-24XS用SFP-10G-LR(1310nm)模块,通过单模跳纤接到同一数据中心内一家一线运营商的二层DWDM设备上。运营商关闭这条电路时,TenGigabitEthernet2/0/23变成'down, line protocol is down (notconnect)',但'show interface transceiver'依然报告RX功率约-5.1/-5.2dBm,和端口up时看到的值一样。'show interfaces'显示'link type is force-up, media type is SFP-10GBase-LR',输入包数为零。接上环回头后端口能up,同一型号的SFP+插在另一台设备上能正确报告DOM,包括无信号时的-40dBm。楼主问这个SFP+模块是不是有问题。

  • 硬件: Cisco Catalyst 3850-24XS (WS-C3850-24XS)
  • 光模块: SFP-10G-LR (SFP-10GBase-LR)
  • 封装形式: SFP+

现象/提示信息:

TenGigabitEthernet2/0/23 is down, line protocol is down (notconnect)
RX power -5.1 dBm reported while port is down
link type is force-up
0 packets input

Comments 4

Accepted answer

结果发现交换机本身没有故障——问题出在我的'monitor capture'测试上。带有发送接口自身MAC地址的环回帧,在到达CPU级抓包之前就已经被交换机丢弃了。

4 South Koreaedgenode14KR Show original (English) AI translation

模块型号、对端设备、距离和光纤类型分别是什么?另外把接上线缆时看到的日志也贴一下。

0 South Koreaedgenode14KR Show original (English) AI translation

运营商具体怎么'关闭'很关键:如果只是关掉了高层业务,光纤上的一层信号仍然可能存在,这就能解释为什么一条已经断掉的电路上RX读数依然稳定。

2 Türkiyedwdmops44TR Show original (English) AI translation

用环回测试:环回后链路能up,同一型号的光模块在别处无信号时读出-40dBm,说明光模块本身没问题;把环回点沿线缆路径逐步往外移,以定位故障点。

2 Kazakhstanlanbyte59KZ Show original (English) AI translation