2votes
2 answers
243views
Several pairs of 3COM 2928 switches (JE007A-like, HP 1910-24G family) were linked over J9281B SFP+ DACs. After upgrading from 5.20 1108P01 to 5.20 1519P03 the links no longer came up. Before the update display transceiver interface showed STACKSFP / Tyco Electronics and simple LINK UPDOWN events…
The poster asked whether third-party optics can be used in an HPE FlexFabric 5700 40XG 2QSFP+ (JG896A) and whether the ProVision command allow-unsupported-transceiver exists on it. The answer clarified how Comware differs from ProVision: there is no allow-list of supported transceivers, so unlisted…
Across about forty ProCurve/Aruba switches the poster had used J4858C and J4858D 1G SX SFPs without issues, but eight newly purchased J4858D units logged Unsupported Transceiver on 2530-8G (J9774A, YA.15.16.0006), 2530-8G (J9777A, YA.15.12.0007) and 2530-24G (J9776A, YA.15.10.0003). show tech…
Four HP ProCurve 6120XG blade switches (516733-B21) refused J9150A 10G SR SFP+ transceivers that the datasheet lists as supported; show tech transceivers reported them as unsupported. The switches ran Z.14.56. The poster asked whether a firmware upgrade or a configuration setting was needed…
While building a trunk between a Cisco Catalyst 3650-48PS and a Catalyst 3560CX-12PC using Cisco GLC-T copper SFPs at both ends, the 3560CX logged '%PHY-4-SFPNOTSUPPORTED: The SFP in Gi0/11 is not supported' and the link would not come up. The poster had already tried 'no errdisable detect cause…
The poster set up several new Cisco Catalyst 9300 switches fitted with C9300-NM-4G network modules, configured GigabitEthernet1/1/1 as a trunk and enabled it, but could not get a link with any of several SFPs. 'show interfaces' reports 'GigabitEthernet1/1/1 is down, line protocol is down…