Four HP ProCurve 6120XG blade switches (516733-B21) refused J9150A 10G SR SFP+ transceivers that the datasheet lists as supported; show tech transceivers reported them as unsupported. The switches ran Z.14.56. The poster asked whether a firmware upgrade or a configuration setting was needed. Hardware involved: HP ProCurve 6120XG (516733-B21), HP J9150A.

  • Hardware: HP ProCurve 6120XG (516733-B21)
  • Transceivers: HP J9150A
  • Form factor: SFP+

Symptoms / messages:

show tech transceivers reports unsupported
genuine module rejected

Comments 2

Accepted answer

An HPE employee pointed to a documented defect where earlier 6120XG firmware wrote to and corrupted transceiver EEPROM values; affected modules stay unusable even after upgrading, because the upgrade only prevents new damage.

1 SpaincoreguruES Original (English)

Since the modules are brand new, I'd suspect counterfeit or damaged units. Open a support case for authenticity verification.

2 Spainrxadmin25ES Original (English)