0votes
1comment
30views

1G optics in MikroTik SFP+ ports: forced 1G fails to an RBFTC11 while auto-negotiation causes FCS errors to a CRS328

Contradicting MikroTik's documented advice to force 1G full duplex when using 1G optics in SFP+ ports, a Netpower Lite 7R linked to an RBFTC11 only with auto-negotiation (forced 1G gave link up but zero received packets), while the same Netpower to a CRS328-4C-20S-4S+ had heavy packet loss and FCS…

3votes
2comments
97views

CCR1036-8G-2S+ shows link OK with 1G SFPs but passes no data; the same modules work on a CCR1036-12G-4S

A MikroTik CCR1036-8G-2S+ with S-31DLC20D 1.25G single-mode SFPs reported link OK but no traffic flowed; TX power was blank and RX was -9 dBm. The identical module on the same fibre worked in a CCR1036-12G-4S. Port disable/enable, forcing 1G full duplex on both ends and support tickets did not…

2votes
1 answer
106views

1G SFP on Intel X710 (pfSense, ixl) fails with unqualified module until the optic is recoded as Intel

On a Protectli Vault 6 with Intel X710 SFP+ ports (ixl0/ixl1) a 1G EZConn ETB43315-7S34-FR SFP showed no carrier. Logs contained Invalid advertised speed; valid flags are: 0x06, ixl1setlink: Error getting phy capabilities -37, aq error: 8 and Link failed because an unqualified module was detected!…