CodingBox Q&A Ask question

Catalyst 3750-X的C3KX-NM-10G模块在某些插槽把GLC-SX-MMD报告为'Not Present'

Asked Active Viewed 112 AI translation from English
4

两台Cisco Catalyst 3750-X交换机(WS-C3750X-24P-L和WS-C3750X-48P-L)跑的是完全相同的代码。第一台交换机的Gi1/1/1能正常识别一个Cisco GLC-SX-MMD,但第二台交换机在Gi1/1/1上报告'media type is Not Present'、'link type is force-up','show idprom interface Gi 1/1/1'的回答是'%No module is present'。同一个模块在两台交换机的多个接口上都试过。shut/no shut、重插、'service unsupported-transceiver'、'no errdisable detect cause gbic-invalid'以及两次重启,都没有任何变化,控制台和日志里也没有出现任何消息。第二台交换机装了一块C3KX-NM-10G网络模块,它的两个10G SFP+槽位已经用作上联,楼主想在剩下的两个槽位里插1G SFP。

  • 硬件: Cisco Catalyst 3750-X (WS-C3750X-24P-L), Cisco Catalyst 3750-X (WS-C3750X-48P-L), Cisco C3KX-NM-10G网络模块
  • 光模块: GLC-SX-MMD, 10G SFP+(未说明具体型号)
  • 封装形式: SFP, SFP+

现象/提示信息:

media type is Not Present
%No module is present
link type is force-up
SFP detected in one switch but not in another running the same code

Comments 5

Accepted answer

被采纳的答案:C3KX-NM-10G模块对它四个槽位上1G SFP和10G SFP+的组合方式是有限制的,这就解释了为什么额外插入的1G模块没有被识别到。

2 Egypttxeng18EG Show original (English) AI translation

按照模块规格,支持的组合是:四个槽位全部插1G SFP;槽位1、2插1G,槽位4插一个10G SFP+;槽位2插一个10G SFP+,槽位3、4插1G;或者只在槽位2和4插10G SFP+。已经装了两个10G模块的情况下,剩下的槽位就不能再插1G SFP了。

3 Egypttxeng18EG Show original (English) AI translation
Log in to comment. Log in