CodingBox Q&A Ask question

Questions tagged “ucg-fiber”

1 question
15 30 50 per page
0votes
1 answer
88views

UCG-Fiber with a UACC-CM-RJ45-MG never recovers the link after the far-end Zyxel XS1930 reboots; DAC fixed it

A UCG-Fiber used a UACC-CM-RJ45-MG 10GBASE-T module (port 6, later port 7) to reach a Zyxel XS1930. Whenever the copper cable was disconnected for more than about 40 s or the Zyxel rebooted, the link never came back until the module was pulled for a minute or the gateway rebooted; forcing 10G or 1G…