HP 6120XG blade switches reject genuine J9150A SFP+ modules after an old firmware corrupted their EEPROM
Four HP ProCurve 6120XG blade switches (516733-B21) refused J9150A 10G SR SFP+ transceivers that the datasheet lists as supported; show tech transceivers reported them as unsupported. The switches ran Z.14.56. The poster asked whether a firmware upgrade or a configuration setting was needed. Hardware involved: HP ProCurve 6120XG (516733-B21), HP J9150A.
- Hardware: HP ProCurve 6120XG (516733-B21)
- Transceivers: HP J9150A
- Form factor: SFP+
Symptoms / messages:
show tech transceivers reports unsupported
genuine module rejected
Comments 2
An HPE employee pointed to a documented defect where earlier 6120XG firmware wrote to and corrupted transceiver EEPROM values; affected modules stay unusable even after upgrading, because the upgrade only prevents new damage.
Since the modules are brand new, I'd suspect counterfeit or damaged units. Open a support case for authenticity verification.