Where to configure the channel on a DWDM-SFP10G-C tunable optic
The poster could not find Cisco documentation describing how to set the frequency or ITU channel of a DWDM-SFP10G-C tunable 10G SFP+. A follow-up question asked whether a CPAK-100G-LR4 in a CRS-X 4-port 100GE LAN/OTN card could be tuned to a wavelength and connected directly to a ROADM of an existing DWDM network. Years later another user upgraded a Nexus 3100 to NX-OS 7.0(3)I7(4), whose release notes list DWDM-SFP10G-C support, but found no way in the documentation to set the wavelength, and noted that the 10G transceiver compatibility guide does not list the optic for that platform.
- Hardware: Cisco Nexus 3100, Cisco CRS-X (4-Port 100GE LAN/OTN line card)
- Transceivers: DWDM-SFP10G-C, CPAK-100G-LR4, 1-100GE-DWDM/C tunable line card
- Form factor: SFP+, CPAK
Symptoms / messages:
no documentation for tuning DWDM-SFP10G-C
no wavelength command found on NX-OS 7.0(3)I7(4)
optic missing from the 10G compatibility guide
Comments 2
On IOS XR the tunig is done under the DWDM controller with 'wavelength {channel-number | frequency | update}' (see the CRS DWDM command reference); 'no wavelength' returns the default.
A CPAK-100G-LR4 uses four wavelengths around 1310 nm multiplexed inside the module, while ROADMs work in the 1550 nm band, so it cannot be connected directly to a ROADM; the CRS offers a tunable 100G DWDM line card (1-100GE-DWDM/C) but no tunable 100G CPAK.