CodingBox Q&A Ask question

HP 5900AF registra OPTMOD/4/PHONY_MODULE para módulos Avago e JDSU 10G SR, enquanto o peer Cisco 6500 mostra input errors

Asked Active Viewed 94 AI translation from English
1

Um HP 5900AF-48XG-4QSFP+ (Comware 7.1.045 R2311P01) registrou OPTMOD/4/PHONY_MODULE: This is not a supported transceiver for this platform para dois módulos SFP+ 10G SR; o display transceiver interface identificou-os como Avago e JDSU 10G_BASE_SR_SFP com DDM. O autor queria saber qual SFP+ comprar e como ler remotamente a peça instalada. Do lado do data center (uma porta TenGigabitEthernet de um Cisco 6500) apareciam 68270 input errors, 68439 giants e um contador de overrun enorme, e as fibras já tinham sido trocadas.

  • Hardware: HPE 5900AF-48XG-4QSFP+, Cisco Catalyst 6500
  • Transceptores: Avago 10G SR SFP+, JDSU 10G SR SFP+
  • Fator de forma: SFP+

Sintomas / mensagens:

OPTMOD/4/PHONY_MODULE: This is not a supported transceiver for this platform
input errors and overruns on peer
giants

Comments 2

Accepted answer

Use display transceiver interface Ten-GigabitEthernet x/y/z para ver vendor e type; o Comware marca ópticas ProCurve/outras marcas, mas elas normalmente funcionam, e vários operadores rodam ópticas não suportadas por anos, mantendo as suportadas apenas nos links IRF.

0 SpainoptictechES Show original (English) AI translation

Compare os contadores de erro dos dois lados; os contadores de overrun e giant do lado Cisco apontam para um problema de tráfego/MTU, não para o transceptor, então trocar a óptica ficou como último recurso.

1 United Stateslinkeng21US Show original (English) AI translation
Log in to comment. Log in