CodingBox Q&A Ask question

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Asked Active Viewed 152 Original language: English
0

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the switch. Server BIOS, i40e/i40en drivers and X710 firmware 19.5.12 were updated without effect. No replies.

  • Hardware: Dell PowerEdge R740xd, Intel X710 (Dell OEM), Cisco switch
  • Transceivers: Cisco SFP-H10GB-CU5M (V02/V03), Cisco SFP-H10GB-CU3M (V02/V03)
  • Form factor: SFP+, DAC

Symptoms / messages:

no link with newer cable revision
same part number, different VID

Comments 0

No comments yet.

Log in to comment. Log in