EdgeSwitch ES-24 will not link to HP/Netgear/Juniper/Cisco over 1G SX SFPs until the peer disables auto-negotiation

Asked Active Viewed 188 Original language: English
0

Newly delivered EdgeSwitch ES-24 units linked to each other over gigabit SX SFPs, but the same modules (HP J4858B, J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ, Cisco) would not link ES-24 to HP ProCurve (four models) or Netgear (two models): the ES-24 showed a link light, the other side did not. Other users reproduced it against Juniper MX routers (optic confirmed receiving light) and a Cisco 3560.

  • Hardware: Ubiquiti EdgeSwitch ES-24, HP ProCurve switches, Netgear managed switches, Juniper MX, Cisco Catalyst 3560
  • Transceivers: HP J4858B, HP J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ
  • Form factor: SFP

Symptoms / messages:

link light only on the EdgeSwitch side
no link to other brands over 1G SX

Comments 2

Accepted answer

Ubiquiti staff: on the HP/Netgear/Juniper/Cisco side disable auto-negotiation and force 1 Gbps (full duplex); this brought links up for several users and a firmware fix was being tested.

7 IndonesiaedgepilotID Original (English)

On stackable Netgear units make sure the SFP+ slot is in Ethernet mode, not stack mode (show stack-port); one HP user needed forced full duplex rather than speed.

4 United Kingdomedgewolf34GB Original (English)