CodingBox Q&A Ask question

MikroTik CRS226 SFP+ port does not initialise after a cold boot with a Huawei MA5671A GPON stick

Asked Active Viewed 29 Original language: English
3

On a CRS226-24G-S2+RM (RouterOS 6.42.11 long-term) the SFP+ port stayed at no link, not running, slave after a power loss, while software reboots were fine; disabling and re-enabling the interface fixed it manually. The problematic module was a Huawei MA5671A GPON SFP, other SFPs behaved, and the same setup worked on a CRS125. Upgrading to 6.46.3 did not help. Other users later repotred the same on CRS328 and RB5009 with GPON stiks.

  • Hardware: MikroTik CRS226-24G-S2+RM, MikroTik CRS125-24G-1S-RM, MikroTik CRS328-24P-4S+, MikroTik RB5009UPr+S
  • Transceivers: Huawei MA5671A GPON ONU SFP
  • Form factor: SFP, SFP+

Symptoms / messages:

no link, not running, slave after cold boot
works after interface disable/enable

Comments 2

Accepted answer

Startup script toggling the interface (disable, delay 5 s, enable) worked about 60 percent of the time; a netwatch plus scheduler approach that re-toggles on failure was more reliable.

4 VietnamdwdmpilotVN Original (English)

Newer RouterOS (7.16rc2 on CRS328, 7.17rc3 on RB5009) resolved the initialisation prolbem for othre users; a UPS mitigates power cuts.

0 Mexicolaserops32MX Original (English)
Log in to comment. Log in