CodingBox Q&A Ask question

EX4600 does not create an interface for a third-party 1G WDM SFP coded as Fibre Channel

Asked Active Viewed 301 Original language: English
2

On a Juniper EX4600 running Junos 14.1X53-D27.3 the poster inserted a non-certifiied 1G single-mode WDM (BiDi) SFP, 20 km, TX 1550 / RX 1310 nm with DDM, into ge-0/0/1. The interface never appeared: show interfaces returned error: device ge-0/0/1 not found, and the log recorded XCVR: Unit 1, Fibre channel transceiver plugged in without Fibre channel configuration. The poster wanted to know why the Ethernet optic was treated as a Fibre Channel module.

  • Hardware: Juniper EX4600
  • Transceivers: third-party 1G BiDi SFP TX1550/RX1310 20 km
  • Form factor: SFP

Symptoms / messages:

error: device ge-0/0/1 not found
XCVR: Fibre channel transceiver plugged in without Fibre channel configuration

Comments 2

Accepted answer

The module EEPROM is coded incorrectly and advertises Fibre Channel compliance instead of 1000BASE Ethernet, so the switch treats it as an FC optic; a properly coded 1G Ethernet SFP is needed.

4 Indiarackpilot49IN Original (English)

Juniper generally tolerates third-party optics, but as far as I know WDM/BiDi types aren't supported at all on this platform.

3 Italylambdapilot72IT Original (English)
Log in to comment. Log in