CodingBox Q&A Ask question

lan_tech

Canada joined 6 months ago 2 questions

Network engineer from Calgary. Mostly CWDM/DWDM rings.

Questions

1vote
3comments
125views

Enabling a third-party transceiver on HPE FlexFabric 5900AF: no CLI switch, ask the supplier to code it for HP 5900

A FlexFabric 5900AF running Comware 7.1.035 R2208P01 reported a third-party transceiver as not supported when inserted, while the same class of modules worked in a FlexFabric 7904 on 7.1.045. The poster asked whether support could be enabled by command and whether the Comware version mattered…

2votes
2comments
158views

Arista 7050QX puts ports with unqualified third-party QSFP+ DACs into errdisable

On an Arista 7050QX running EOS 4.14 the poster tried to use third-party QSFP+ DAC cables; the ports went to errdisable as unqualified transceivers. They patched the XcvrAgent.py agent under /usr/lib/python2.7/site-packages to skip the manufacturer check, which cleared the errdisable state but left…