Spectrum SN2100/SN2700 under Linux switchdev: mlxsw_spectrum-13.2014.4012 firmware breaks ethtool -m (Failed to access module's EEPROM)

Asked Active Viewed 85 Original language: English
2

On first-generation Spectrum switches (SN2100, SN2700) running upstream Linux with the mlxsw switchdev driver (Ubuntu 25.10 / kernel 6.17, also 24.04 and OpenWrt), updating to the latest linux-firmware blob mlxsw_spectrum-13.2014.4012.mfa2 (and the fw-2016.1116 build from the SONiC SDK bins) makes ethtool -m enp1s0np1 fail with "netlink error: mlxsw_core: Failed to access module's EEPROM" / "Input/output error", while dmesg shows EMAD reg access failed ... reg_id=9014(mcia) ... status=7(bad parameter). Spectrum-2 SN3420/SN3700 on their latest firmware are unaffected, and reverting to mlxsw_spectrum-13.2012.1012.mfa2 restores EEPROM reads. Is this a known regression?

Comments 2

The source describes a Spectrum-1 firmware regression affecting MCIA EEPROM access, with ethtool -m failing after the firmware change. A cabel replacement cannot fix a driver/firmware register-access error.

3 Spainqsfpwolf31ES Original (English)

The reported fixes were in 2016.2066 and confirmed on 2016.2096; the previously working blob was 13.2012.1012. Verify the applicable fixed image and retain a known-good firmware path when updating an affected switchdev installation.

1 United StatesqsfpwolfUS Original (English)
Log in to comment. Log in