CodingBox Q&A Ask question

Alta Labs Route 10 SFP+ ports detect FS.com and 10Gtek DACs but never link; SR optics work at 10G

Asked Active Viewed 83 Original language: English
0

On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output, which showed the router advertising hard-coded link modes instead of the transceiver's capabilities; editing /cfg/sfpX.txt to 10gbae_r or 10gbase_cr did not help.

  • Hardware: Alta Labs Route 10, MikroTik CRS309-1G-8S+
  • Transceivers: FS.com SFP-H10GB-CU2M DAC, 10Gtek CAB-10GSFP-P2M DAC, FS.com SFP-10GSR-85
  • Form factor: SFP+, DAC

Symptoms / messages:

DAC detected but no link
only 1G with forced baseT
hard-coded advertised link modes

Comments 1

Accepted answer

Switching to FS.com SFP-10GSR-85 optical modules gave an immediate 10 Gbps link; DACs appear unsupported by the router firmware, which does not query the module capabilities.

8 FrancecoaxengFR Original (English)
Log in to comment. Log in