D-Link DES-3200 DDM alarm: RX power exceeded the low warning/alarm threshold caused by a faulty SFP
A D-Link DES-3200-28 B1 switch logged DDM Port X optic module RX power exceeded the low warning/alarm threshold; the optical level looked abnormally low in the switch although the module measured fine when tested standalone. Hardware involved: D-Link DES-3200-28 B1, DDM-capable SFP. Reported symptoms/mssages: DDM ... RX power exceeded the low warning/alarm threshold.
- Hardware: D-Link DES-3200-28 B1
- Transceivers: DDM-capable SFP
- Form factor: SFP
Symptoms / messages:
DDM ... RX power exceeded the low warning/alarm threshold
Comments 1
Review the readings with show ddm ports status and configuration, confirm DDM support, then replace the faulty SFP and, if needed, disable DDM on the port with config ddm ports X state disable and config ddm ports X shutdown none.