UniFi SFP Wizard web GUI: read/back up/write SFP EEPROM, limited to modules in the password database

Asked Active Viewed 40 Original language: English
2

A web-based (Web Bluetooth) GUI for the UniFi SFP-Wizard device that reads SFP EEPROM, saves backups as .uieeprom files and writes from a prior backup. Limitations: the API does not flash directly; the dump goes to the device snapshot buffer for manual confirmation on the hardware; newer firmware only flashes modules whose part number is in the password database (Ubiquiti-branded parts, not third-party); modules inserted during boot cannot be read; a local backup must exist before writing.

  • Hardware: UniFi SFP-Wizard device
  • Transceivers: Ubiquiti-branded SFP, third-party SFP (unsupported)
  • Form factor: SFP

Symptoms / messages:

unsigned/unknown module cannot be flashed
module not read if inserted at boot

Comments 1

Accepted answer

Back up the module (a local .uieeprom backup is mandatory before any write), then push the dump to the snapshot buffer and confirm on the physical Wizard; only database-listed (Ubiquiti) part numbers can be flashed.