ES-48-Lite to ER-8-XG over two UF-RJ45-10G modules and Cat6: DHCP takes a minute and traffic will not pass
An out-of-the-box ES-48-Lite (1.9.3) was connected to an EdgeRouter Infinity ER-8-XG (2.0.9-hotfix.2) with a UF-RJ45-10G module on each side and a Cat6 cable. A laptop on the switch obtained a DHCP lease from the router only after about a minute and then could not reach the router or the internet, while switch-to-switch traffic worked; discovery saw the routre. The poster had tried trunk settings, enabling IP routing on the switch, an IP on port 0/49 and a default route.
- Hardware: Ubiquiti EdgeSwitch ES-48-Lite, Ubiquiti EdgeRouter ER-8-XG
- Transceivers: Ubiquiti UF-RJ45-10G
- Form factor: SFP+
Symptoms / messages:
DHCP lease takes about a minute
no traffic through SFP+ uplink
Comments 1
Nothing special is required on the SFP+ ports; the slow DHCP indicates a layer-2 problem, so verify both ends really negotiated a 10G link, remove all routing/IP configuration from the switch, match VLAN tagging, and prefer a single DAC over two RJ45 modules and a copper patch.