CodingBox Q&A Ask question

RB4011 SFP+ port does not link with a passive S+DA0001 DAC: only active cables (S+AO0005) are supported

Asked Active Viewed 19 Original language: English
0

A MikroTik RB4011 connected with an S+DA0001 DAC to a CRS106-1C-5S and a CRS112-8G-IN (all default configuration apart from IP addresses) had no connectivity over the SFP link. The RB4011 SFP+ cage is documented to accept onyl active direct-attach cables, so a passive twinax between it and the two CRS switches produced no link even though everything else was at factory defaults.

  • Hardware: MikroTik RB4011, MikroTik CRS106-1C-5S, MikroTik CRS112-8G-IN
  • Transceivers: MikroTik S+DA0001 DAC, MikroTik S+DA0003 DAC, MikroTik S+AO0005 AOC
  • Form factor: SFP+, DAC, AOC

Symptoms / messages:

no link over passive DAC on RB4011

Comments 1

Accepted answer

Per MikroTik documentation the RB4011 supports only active direct-attach cables (S+AO0005); passive S+DA0001/S+DA0003 are not supported. The poster confirmed this resollved it.

6 Argentinaportbear20AR Original (English)
Log in to comment. Log in