BiDi SFPs on a CRS326-24G-2S+ (SwOS): light received at -6 dBm but no link until auto-negotiation is disabled
Two FS.com 1G BiDi SFPs (1490/1310 and 1310/1490 nm) in a MikroTik CRS326-24G-2S+ running SwOS 2.9 detected incoming light around -6 dBm but never established a link; the same optics linked on a Netgear switch. The poster asked whether a manual speed setting was needed and whether RouterOS would behave differently.
- Hardware: MikroTik CRS326-24G-2S+, Netgear switch
- Transceivers: FS.com 1G BiDi SFP 1310/1490, FS.com 1G BiDi SFP 1490/1310, MikroTik 1.25G BiDi 1310/1550
- Form factor: SFP
Symptoms / messages:
RX power -6 dBm but no link
Comments 1
Disable auto-negotiation and set the port to a fixed 1G - it's documented in the wiki. MikroTik's own BiDi optics use the 1310/1550 pairing.